Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 429
Filtrar
1.
Eur Radiol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634875

RESUMO

PURPOSE: To compare the diagnostic approach of acute pulmonary embolism (PE) with photon-counting-detector CT (PCD-CT) and energy-integrating-detector CT (EID-CT). MATERIALS AND METHODS: Two cohorts underwent CT angiographic examinations with EID-CT (Group 1; n = 158) and PCD-CT (Group 2; n = 172), (b) with two options in Group 1, dual energy (Group 1a) or single energy (Group 1b) and a single option in Group 2 (spectral imaging with single source). RESULTS: In Group 2, all patients benefited from spectral imaging, only accessible to 105 patients (66.5%) in Group 1, with a mean acquisition time significantly shorter (0.9 ± 0.1 s vs 4.0 ± 0 .3 s; p < 0.001) and mean values of CTDIvol and DLP reduced by 46.3% and 47.7%, respectively. Comparing the quality of 70 keV (Group 2) and averaged (Group 1a) images: (a) the mean attenuation within pulmonary arteries did not differ (p = 0.13); (b) the image noise was significantly higher (p < 0.001) in Group 2 with no difference in subjective image noise (p = 0.29); and (c) 89% of examinations were devoid of artifacts in Group 2 vs 28.6% in Group 1a. The percentage of diagnostic examinations was 95.2% (100/105; Group 1a), 100% (53/53; Group 1b), and 95.3% (164/172; Group 2). There were 4.8% (5/105; Group 1a) and 4.7% (8/172; Group 2) of non-diagnostic examinations, mainly due to the suboptimal quality of vascular opacification with the restoration of a diagnostic image quality on low-energy images. CONCLUSION: Compared to EID-CT, morphology and perfusion imaging were available in all patients scanned with PCD-CT, with the radiation dose reduced by 48%. CLINICAL RELEVANCE STATEMENT: PCD-CT enables scanning patients with the advantages of both spectral imaging, including high-quality morphologic imaging and lung perfusion for all patients, and fast scanning-a combination that is not simultaneously accessible with EID-CT while reducing the radiation dose by almost 50%.

2.
Adv Sci (Weinh) ; : e2310277, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520722

RESUMO

Poloxamers are amphiphilic block copolymers consisting of poly(ethylene glycol) (PEG) and poly(propylene glycol) segments. Their self-assembly and interfacial properties are tied to the relative hydrophilicity and hydrophobicity of each block and can therefore be adjusted by changing block lengths. Here, a series of PEG-polycycloether block copolymers is synthesized that have the same structure as a poloxamer, but they encompass a rigid polycyclic backbone as the hydrophobic block. A variety of polymer structures are synthesized, for example diblock or triblock architectures, with/without olefinic units, atactic or isotactic backbone, and different block lengths. Due to their amphiphilicity, self-assembly into spherical aggregates (diameters ranging from 64 to 132 nm) at low concentrations (critical aggregation concentration as low as 0.04 mg mL-1) is observed in water. Low surface tensions (as low as 26.7 mN m-1) are observed as well as the formation of stable high internal phase emulsions (HIPEs) irrespective of the oil/water ratio. This contrasts with the properties of the commonly used poloxamers P188 or P407 and illustrates the significance of the rigid polycycloether block. These new colloidal properties offer new prospects for applications in emulsion formulations for biomedicine, cosmetics, and the food industry.

3.
Heliyon ; 10(6): e27636, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38509988

RESUMO

Rationale and objectives: Coronary computed tomography angiography (CCTA) is becoming increasingly important for the diagnostic workup of coronary artery disease, nevertheless, imaging of in-stent stenosis remains challenging. For the first time, spectral imaging in Ultra High Resolution (UHR) is now possible in clinically available photon counting CT. The aim of this work is to determine the optimal virtual monoenergetic image (VMI) for imaging in-stent stenoses in cardiac stents. Materials and methods: 6 stents with inserted hypodense stenoses were scanned in an established phantom in UHR mode. Images were reconstructed with 3 different kernels for spectral data (Qr56, Qr64, Qr72) with varying levels of sharpness. Based on region of interest (ROI) measurements image quality parameters including contrast-to-noise ratio (CNR) were analyzed for all available VMI (40 keV-190 keV). Finally, based on quantitative results and VMI used in clinical routine, a set of VMI was included in a qualitative reading. Results: CNR showed significant variations across different keV levels (p < 0.001). Due to reduced noise there was a focal maximum in the VMI around 65 keV. The peak values were observed for kernel Qr56 at 116 keV with 19.47 ± 8.67, for kernel Qr64 at 114 keV with 13.56 ± 6.58, and for kernel Qr72 at 106 keV with 12.19 ± 3.25. However, in the qualitative evaluation the VMI with lower keV (55 keV) performed best. Conclusions: Based on these experimental results, a photon counting CCTA in UHR with stents should be reconstructed with the Qr72 kernel for the assessment of in-stent stenoses, and a VMI 55 keV should be computed for the evaluation.

4.
Invest Radiol ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38526041

RESUMO

OBJECTIVES: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. MATERIALS AND METHODS: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. RESULTS: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions (R2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. CONCLUSIONS: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as-in distinction to iodine-both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.

5.
AJR Am J Roentgenol ; 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38323783

RESUMO

Background: Use of virtual monoenergetic images (VMIs) from multi-energy CT scans can mitigate inconsistencies in traditional attenuation measurements that result from variation in scan-related factors. Photon-counting detector (PCD) CT systems produce VMIs as standard image output under flexible scanning conditions. Objective: To evaluate the consistency of monoenergetic attenuation measurements obtained from a clinical PCD CT scanner across a spectrum of scanning paradigms. Methods: A phantom with ten tissue-simulating inserts was imaged using a clinical dual-source PCD CT scanner. Nine scanning paradigms were obtained across combinations of tube voltages (90, 120, and 140 kVp) and image quality (IQ) levels (80, 145, and 180). Images were reconstructed at VMI levels of 50, 60, 70, and 80 keV. Consistency of attenuation measurements was assessed, using the 120-kVp IQ-145 scanning paradigm as the reference scan. Results: For all scanning paradigms, attenuation measurements showed intraclass correlation ≥0.999 with respect to the reference scan. Across inserts, mean bias relative to the reference scan ranged from -14.9 to 13.6 HU, -2.7 to 1.7 HU, and -3.9 to 3.8 HU at tube voltages of 90, 120, and 140 kVp; and from -14.9 to 13.6 HU, -6.4 to 3.8, -3.7 to 1.4, and -7.2 to 4.3 HU at VMI levels of 50, 60, 70, and 80 keV. Thus, mean bias did not exceed 5 HU for any insert at tube potentials of 120 kVp and 140 kVp, nor for any insert at a VMI level of 70 keV. At a VMI level of 50 keV and tube potential of 90 kVp, mean bias exceeded 5 HU for 14 of 30 possible combinations of inserts and scanning paradigms, and exceeded 10 HU for 4 of 30 such combinations. At VMI levels of both 60 and 80 keV, mean bias exceeded 5 HU for only two combinations of inserts and scanning paradigms, all at a tube potential of 90 kVp. Conclusion: PCD CT generally provided consistent attenuation measurements across combinations of scanning paradigms and VMI levels. Clinical Impact: PCD CT may facilitate quantitative applications of CT data in clinical practice.

6.
Transplantation ; 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38227773

RESUMO

BACKGROUND: Children requiring kidney replacement therapy experience high burden of cardiovascular (CV) disease leading to increased mortality. Intima-media thickness (IMT) indicating atherosclerosis is a validated surrogate marker for future CV events. METHODS: We investigated the effect of different treatment modalities (dialysis, preemptive kidney transplantation (KTx), late KTx after dialysis) on IMT by multivariable linear mixed-effect modeling. Patients were enrolled in a prospective cohort study. RESULTS: A total of 261 analyzed children had a mean follow-up of 3 y. Children after preemptive and late KTx had lower levels of IMT when compared with dialysis. Using an interaction term, a significant progression of IMT over time was seen during dialysis (ß = 0.0053 mm/y, P  =  0.004). IMT before the start of therapy was the most influential determinant in all models. Low IMT was associated with maintenance steroid treatment after preemptive KTx. High IMT on dialysis was associated with higher systolic blood pressure, lower body mass index, lower serum albumin, and lower bicarbonate. CONCLUSIONS: IMT remained rather stable in children several years after KTx. In contrast, children on dialysis had higher IMT values, which increased over time. In these children, blood pressure control, calorie and protein intake, and acid-base homeostasis seem important. Taken together, children might profit from early transplantation to limit accumulation of CV risk.

7.
Cardiovasc Res ; 120(1): 108-119, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-37890022

RESUMO

AIMS: Resistant hypertension is associated with a high risk of cardiovascular disease, chronic kidney disease, and mortality. Yet, its management is challenging. This study aims to establish the comparative effectiveness of pharmacologic and interventional treatments by conducting a network meta-analysis. METHODS AND RESULTS: MEDLINE, Cochrane Register of Controlled Trials, and Web of Science Core Collection were systematically searched in March 2022. Randomized controlled trials comparing treatment options for management of resistant hypertension were included. Outcomes were blood pressure (BP) changes, measured in the office and in 24 h ambulatory BP measurement. We applied a frequentist random effects model to perform a network meta-analysis combining placebo medication and sham procedure as the reference comparator. From 4771 records, 24 studies met the inclusion criteria with 3458 included patients in total. Twelve active treatment alternatives [spironolactone, doxazosin, ß-blocker, clonidine, darusentan, guanfacine, various types of renal sympathetic denervation, lifestyle intervention, continuous positive airway pressure, and baroreflex activation therapy (BAT)] were analysed. Among all comparators, spironolactone had the highest ranking probability and was considered the most effective treatment to reduce office systolic blood pressure (sBP) [-13.30 mmHg (-17.89; -8.72); P < 0.0001] and 24 h sBP [-8.46 mmHg (-12.54; -4.38); P < 0.0001] in patients with resistant hypertension. Lifestyle interventions were the most effective non-pharmacological treatment, lowering office sBP by -7.26 mmHg (-13.73; -0.8), whereas BAT lowered office sBP by -7.0 (-18.59; 4.59). Renal denervation lowered office sBP by -5.64 mmHg (-12.95; 1.66) and -3.79 mmHg (-11.39; 3.8) depending on the type of the procedure. CONCLUSION: Among all pharmacologic and interventional treatments, spironolactone is the most effective treatment in reducing BP in patients with resistant hypertension. More comparative trials and especially trials with long-term follow-up are needed. In the meanwhile, we have to conclude that a combination of spironolactone and lifestyle modification are the most effective treatments in resistant hypertension.


Assuntos
Hipertensão , Espironolactona , Humanos , Espironolactona/farmacologia , Metanálise em Rede , Anti-Hipertensivos/efeitos adversos , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Pressão Sanguínea , Rim , Resultado do Tratamento
8.
Pediatr Nephrol ; 39(5): 1587-1598, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38103064

RESUMO

BACKGROUND: Cardiovascular (CV) morbidity after kidney transplantation (KTx) in childhood is of increasing importance. In light of a high prevalence of CV risk factors, protective measures such as physical activity (PA) come into focus. Our aim was to comprehensively assess PA in pediatric KTx recipients and evaluate its impact on CV health. METHODS: Forty-eight patients were assessed for frequency, duration, intensity, and setting of PA using the "Motorik-Modul" PA questionnaire. Walking-based activity was measured by accelerometer in a subgroup (n = 23). CV risk factors and subclinical CV organ damage were determined. The impact of PA on CV parameters was analyzed using linear regression models. RESULTS: Fifty-two percent of pediatric KTx recipients did not reach WHO recommended PA level; 54% did not engage in PA with vigorous intensity (VPA). Twenty-nine percent indicated an extremely inactive lifestyle (< 120 min/week of moderate to vigorous intensity PA, MVPA). Compared to the healthy German KiGGS cohort, KTx recipients specifically lacked engagement in sport activities (KTx: 129 min/week; 95%CI, 97-162 vs. KiGGS, 242 min/week; 95%CI, 230-253). VPA was associated with lower systolic blood pressure (p = 0.024) and resting heart rate (p = 0.005), MVPA with fewer components of the post-transplant metabolic syndrome (p = 0.037), and better left ventricular diastolic function (p = 0.006). CONCLUSIONS: A considerable lack of PA, especially VPA, exists in young KTx recipients. PA was positively associated with important parameters of CV health. While long-term CV protection through PA seems promising in pediatric KTx recipients, specific educational approaches are most likely needed to increase patients' engagement in sport activities.


Assuntos
Transplante de Rim , Síndrome Metabólica , Humanos , Criança , Transplante de Rim/efeitos adversos , Exercício Físico/fisiologia , Síndrome Metabólica/epidemiologia , Síndrome Metabólica/etiologia , Pressão Sanguínea , Transplantados
10.
PLoS One ; 18(11): e0293183, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37917640

RESUMO

BACKGROUND: Diabetic kidney disease (DKD) is a health burden of rising importance. Slowing progression to end stage kidney disease is the main goal of drug treatment. The aim of this analysis is to compare drug treatments of DKD by means of a systemic review and a network meta-analysis. METHODS: We searched Medline, CENTRAL and clinicaltrials.gov for randomized, controlled studies including adults with DKD treated with the following drugs of interest: single angiotensin-converting-enzyme-inhibitor or angiotensin-receptor-blocker (single ACEi/ARB), angiotensin-converting-enzyme-inhibitor and angiotensin-receptor-blocker combination (ACEi+ARB combination), aldosterone antagonists, direct renin inhibitors, non-steroidal mineralocorticoid-receptor-antagonists (nsMRA) and sodium-glucose cotransporter-2 inhibitors (SGLT2i). As primary endpoints, we defined: overall mortality and end-stage kidney disease, as secondary endpoints: renal composite outcome and albuminuria and as safety endpoints: acute kidney injury, hyperkalemia and hypotension. Under the use of a random effects model, we computed the overall effect estimates using the statistic program R4.1 and the corresponding package "netmeta". Risk of bias was assessed using the RoB 2 tool and the quality of evidence of each pairwise comparison was rated according to GRADE (Grading of Recommendations Assessment, Development and Evaluation). RESULTS: Of initial 3489 publications, 38 clinical trials were found eligible, in total including 42346 patients. Concerning the primary endpoints overall mortality and end stage kidney disease, SGLT2i on top of single ACEi/ARB compared to single ACEi/ARB was the only intervention significantly reducing the odds of mortality (OR 0.81, 95%CI 0.70-0.95) and end-stage kidney disease (OR 0.69, 95%CI 0.54-0.88). The indirect comparison of nsMRA vs SGLT2i in our composite endpoint suggests a superiority of SGLT2i (OR 0.60, 95%CI 0.47-0.76). Concerning safety endpoints, nsMRA and SGLT2i showed benefits compared to the others. CONCLUSIONS: As the only drug class, SGLT2i showed in our analysis beneficial effects on top of ACEi/ARB treatment regarding mortality and end stage kidney disease and by that reconfirmed its position as treatment option for diabetic kidney disease. nsMRA reduced the odds for a combined renal endpoint and did not raise any safety concerns, justifying its application.


Assuntos
Diabetes Mellitus , Nefropatias Diabéticas , Falência Renal Crônica , Inibidores do Transportador 2 de Sódio-Glicose , Adulto , Humanos , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/farmacologia , Nefropatias Diabéticas/tratamento farmacológico , Antagonistas de Receptores de Angiotensina/uso terapêutico , Antagonistas de Receptores de Angiotensina/farmacologia , Metanálise em Rede , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Falência Renal Crônica/tratamento farmacológico , Angiotensinas , Diabetes Mellitus/tratamento farmacológico
11.
Br J Radiol ; 96(1152): 20230407, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37750856

RESUMO

CT of the heart, in particular ECG-controlled coronary CT angiography (cCTA), has become clinical routine due to rapid technical progress with ever new generations of CT equipment. Recently, CT scanners with photon-counting detectors (PCD) have been introduced which have the potential to address some of the remaining challenges for cardiac CT, such as limited spatial resolution and lack of high-quality spectral data. In this review article, we briefly discuss the technical principles of photon-counting detector CT, and we give an overview on how the improved spatial resolution of photon-counting detector CT and the routine availability of spectral data can benefit cardiac applications. We focus on coronary artery calcium scoring, cCTA, and on the evaluation of the myocardium.


Assuntos
Coração , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Coração/diagnóstico por imagem , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Fótons
12.
Hypertension ; 80(9): 1900-1908, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37462031

RESUMO

BACKGROUND: We assessed the effect of blood pressure (BP) control on left ventricular mass index (LVMI) and left ventricular hypertrophy (LVH). METHODS: Ninety-six patients (64 males) ≥9 months post-kidney transplantation from the 4C-T (Cardiovascular Comorbidity in Children with Chronic Kidney Disease and Transplantation) study were analyzed longitudinally (mean follow-up, 2.6±1.3 years). Cumulative systolic blood pressure (SBP)/diastolic BP exposure was calculated as a time-averaged area under the curve and categorized: ≤50th, 50th to ≤75th, 75th to ≤90th, and >90th percentile (pct). We performed adjusted linear and logistic mixed models for LVMI and LVH, respectively. RESULTS: At baseline, LVMI was 49.7±12.7g/m2.16 with 64% (n=61) kidney transplantation recipients displaying LVH. Compared with patients with cumulative SBP exposure >90th pct, patients with cumulative SBP of 50th to ≤75th showed a significant LVMI reduction of -5.24g/m2.16 (P=0.007). A similar tendency was seen for cumulative SBP≤50th (ß=-3.70 g/m2.16; P=0.067), but patients with cumulative SBP of 75th to ≤90th pct showed no reduction. A post hoc analysis in patients with cumulative SBP≤75th revealed that median SBP exposure was at 57.5th pct. For cumulative diastolic BP, a significant LVMI reduction was seen in all 3 categories ≤90th pct compared with patients >90th pct. Patients with cumulative SBP of ≤50th or 50th to ≤75th pct showed 79% or 83% lower odds of developing LVH, respectively. Patients with cumulative diastolic BP ≤50th showed a tendency of 82% lower odds for LVH (95% CI, 0.03-1.07). CONCLUSIONS: Stricter BP control led to regression of LVMI and LVH. Our data suggest a BP target below the 60th pct, which needs to be substantiated in a randomized controlled trial.


Assuntos
Hipertensão , Transplante de Rim , Insuficiência Renal Crônica , Criança , Humanos , Masculino , Pressão Sanguínea/fisiologia , Comorbidade , Hipertensão/diagnóstico , Hipertensão/epidemiologia , Hipertensão/complicações , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/complicações , Transplante de Rim/efeitos adversos , Insuficiência Renal Crônica/epidemiologia , Estudos Longitudinais
13.
Eur J Radiol ; 166: 110983, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37480648

RESUMO

PURPOSE: Imaging stents and in-stent stenosis remains a challenge in coronary computed tomography angiography (CCTA). In comparison to conventional Computed Tomography, Photon Counting CT (PCCT) provides decisive clinical advantages, among other things by providing low dose ultra-high resolution imaging of coronary arteries. This work investigates the image quality in CCTA using clinically established kernels and those optimized for the imaging of cardiac stents in PCCT, both for in-vitro stent imaging in 400 µm standard resolution mode (SRM) and 200 µm Ultra High Resolution Mode (UHR). METHODS: Based on experimental scans, vascular reconstruction kernels (Bv56, Bv64, Bv72) were optimized. In an established phantom, 10 different coronary stents with 3 mm diameter were scanned in the first clinically available PCCT. Scans were reconstructed with clinically established and optimized kernels. Four readers measured visible stent lumen, performed ROI-based density measurements and rated image quality. RESULTS: Regarding the visible stent lumen, UHR is significantly superior to SRM (p < 0.001). In all levels, the optimized kernels are superior to the clinically established kernels (p < 0.001). One optimized kernel showed a significant reduction of noise compared to the clinically established kernels. Overall image quality is improved with optimized kernels. CONCLUSIONS: In a phantom study PCCT UHR with optimized kernels for stent imaging significantly improves the ability to assess the in-stent lumen of small cardiac stents. We recommend using UHR with an optimized sharp vascular reconstruction kernel (Bv72uo) for imaging of cardiac stent.


Assuntos
Angiografia , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Angiografia por Tomografia Computadorizada , Stents
14.
Front Cardiovasc Med ; 10: 1081675, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37332595

RESUMO

Introduction: Cardiovascular disease remains the most common cause of death worldwide, and early manifestations are increasingly identified in childhood and adolescence. With physical inactivity being the most prevalent modifiable risk factor, the risk for cardiovascular disease is deemed low in people engaging in regular physical exercise. The aim of this study was to investigate early markers and drivers of cardiovascular disease in young athletes pursuing a career in competitive sports. Methods: One hundred and five athletes (65 males, mean age 15.7 ± 3.7 years) were characterized by measurement of body impedance to estimate body fat, blood pressure (BP), carotid femoral pulse wave velocity (PWV) to evaluate arterial elasticity, ergometry to assess peak power output, echocardiography to calculate left ventricular mass, and blood tests. Results: Systolic BP was elevated in 12.6% and thereby more than twice as high as expected for the normal population. Similarly, structural vascular and cardiac changes represented by elevated PWV and left ventricular mass were found in 9.5% and 10.3%. Higher PWV was independently associated with higher systolic BP (ß = 0.0186, p < 0.0001), which in turn was closely correlated to hemoglobin levels (ß = 0.1252, p = 0.0435). In this population, increased left ventricular mass was associated with lower resting heart rate (ß = -0.5187, p = 0.0052), higher metabolic equivalent hours (ß = 0.1303, p = 0.0002), sport disciplines with high dynamic component (ß = 17.45, p = 0.0009), and also higher systolic BP (ß = 0.4715, p = 0.0354). Conclusion: Despite regular physical exercise and in the absence of obesity, we found an unexpected high rate of cardiovascular risk factors. The association of PWV, systolic BP, and hemoglobin suggested a possible link between training-induced raised hemoglobin levels and altered vascular properties. Our results point toward the need for thorough medical examinations in this seemingly healthy cohort of children and young adults. Long-term follow-up of individuals who started excessive physical exercise at a young age seems warranted to further explore the potential adverse effects on vascular health.

15.
Acad Radiol ; 30(12): 2962-2972, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37179206

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate the diagnostic utility of iterative metal artifact reduction (iMAR) in computed tomography (CT)-imaging of oral and oropharyngeal cancers when obscured by dental hardware artifacts and to determine the most appropriate iMAR settings for this purpose. MATERIALS AND METHODS: The study retrospectively enrolled 27 patients (8 female, 19 male; mean age 64±12.7years) with histologically confirmed oral or oropharyngeal cancer obscured by dental artifacts in contrast-enhanced CT. Raw CT data were reconstructed with ascending iMAR strengths (levels 1/2/3/4/5) and one reconstruction without iMAR (level 0). For subjective analysis, two blinded radiologists rated tumor visualization and artifact severity on a five-point Likert scale. For objective analysis, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and artifact index (AI) were determined. RESULTS: iMAR reconstructions improved the subjective image quality of tumor edge and contrast, and the objective parameters of tumor SNR and CNR, reaching their optimum at iMAR levels 4 and 5 (P<.001). AI decreased with iMAR reconstructions reaching its minimum at iMAR level 5 (P<.001). Tumor detection rates increased 2.4-fold with iMAR 5, 2.1-fold with iMAR 4, and 1.9-fold with iMAR 3 compared to reconstructions without iMAR. Disadvantages such as algorithm-induced artifacts increased significantly with higher iMAR strengths (P<.05), reaching a maximum with iMAR 5. CONCLUSION: iMAR significantly improves CT imaging of oral and oropharyngeal cancers, as confirmed by both subjective and objective measures, with best results at highest iMAR strengths.


Assuntos
Artefatos , Neoplasias Orofaríngeas , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Metais , Tomografia Computadorizada por Raios X/métodos , Neoplasias Orofaríngeas/diagnóstico por imagem , Algoritmos
16.
Invest Radiol ; 58(7): 441-450, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37185302

RESUMO

ABSTRACT: Novel photon-counting detector CT (PCD-CT) has the potential to address the limitations of previous CT systems, such as insufficient spatial resolution, limited accuracy in detecting small low-contrast structures, or missing routine availability of spectral information. In this review article, we explain the basic principles and potential clinical benefits of PCD-CT, with a focus on recent literature that has grown rapidly since the commercial introduction of a clinically approved PCD-CT.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Imagens de Fantasmas
17.
Crit Care ; 27(1): 215, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-37259160

RESUMO

INTRODUCTION: Cytokine adsorption using the CytoSorb® adsorber has been proposed in various clinical settings including sepsis, ARDS, hyperinflammatory syndromes, cardiac surgery or recovery after cardiac arrest. The aim of this analysis is to provide evidence for the efficacy of the CytoSorb® adsorber with regard to mortality in various settings. METHODS: We searched PubMed, Cochrane Library database and the database provided by Cytosorbents™ (01.1.2010-29.5.2022). We considered randomized controlled trials and observational studies with control groups. The longest reported mortality was defined as the primary endpoint. We computed risk ratios and 95%-confidence intervals and used DerSimonian and Lairds random effects model. We analysed all studies combined and divided them into the subgroups: sepsis, cardiopulmonary bypass surgery (CPB), other severe illness, SARS-CoV-2 infection and recovery from cardiac arrest. The meta-analysis was registered in advance (PROSPERO: CRD42022290334). RESULTS: Of an initial 1295 publications, 34 studies were found eligible, including 1297 patients treated with CytoSorb® and 1314 controls. Cytosorb® intervention did not lower mortality (RR [95%-CI]: all studies 1.07 [0.88; 1.31], sepsis 0.98 [0.74; 1.31], CPB surgery 0.91 [0.64; 1.29], severe illness 0.95 [0.59; 1.55], SARS-CoV-2 1.58 [0.50; 4.94]). In patients with cardiac arrest, we found a significant survival advantage of the untreated controls (1.22 [1.02; 1.46]). We did not find significant differences in ICU length of stay, lactate levels, or IL-6 levels after treatment. Of the eligible 34 studies only 12 were randomized controlled trials. All observational studies showed moderate to serious risk of bias. INTERPRETATION: To date, there is no evidence for a positive effect of the CytoSorb® adsorber on mortality across a variety of diagnoses that justifies its widespread use in intensive care medicine.


Assuntos
Adsorção , Ponte Cardiopulmonar , Citocinas , Citocinas/efeitos adversos , Citocinas/sangue , Citocinas/metabolismo , Cirurgia Torácica , Complicações Pós-Operatórias/prevenção & controle
18.
Invest Radiol ; 58(11): 767-774, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37222522

RESUMO

PURPOSE: The aim of this study was to assess the effect of temporal resolution on subjective and objective image quality of coronary computed tomography angiography (CCTA) in the ultra-high-resolution (UHR) mode with dual-source photon-counting detector (PCD) CT. MATERIALS AND METHODS: This retrospective, institutional review board-approved study evaluated 30 patients (9 women; mean age, 80 ± 10 years) undergoing UHR CCTA with a clinical dual-source PCD-CT scanner. Images were acquired with a tube voltage of 120 kV and using a collimation of 120 × 0.2 mm. Gantry rotation time was 0.25 seconds. Each scan was reconstructed using both single-source and dual-source data resulting in an image temporal resolution of 125 milliseconds and 66 milliseconds, respectively. The average heart rate and the heart rate variability were recorded. Images were reconstructed with a slice thickness of 0.2 mm, quantum iterative reconstruction strength level 4, and using the Bv64 and Bv72 kernel for patients without and with coronary stents, respectively. For subjective image quality, 2 experienced readers rated motion artifacts and vessel delineation, or in-stent lumen visualization using 5-point discrete visual scales. For objective image quality, signal-to-noise ratio, contrast-to-noise ratio, stent blooming artifacts, and vessel and stent sharpness were quantified. RESULTS: Fifteen patients had coronary stents, and 15 patients had no coronary stents. The mean heart rate and heart rate variability during data acquisition were 72 ± 10 beats per minute and 5 ± 6 beats per minute, respectively. Subjective image quality in the right coronary artery, left anterior descending, and circumflex artery was significantly superior in 66 milliseconds reconstructions compared with 125 milliseconds reconstructions for both readers (all P 's < 0.01; interreader agreement, Krippendorff α = 0.84-1.00). Subjective image quality deteriorated significantly at higher heart rates for 125 milliseconds (ρ = 0.21, P < 0.05) but not for 66 milliseconds reconstructions (ρ = 0.11, P = 0.22). No association was found between heart rate variability and image quality for both 125 milliseconds (ρ = 0.09, P = 0.33) and 66 milliseconds reconstructions (ρ = 0.13, P = 0.17), respectively. Signal-to-noise ratio and contrast-to-noise ratio were similar between 66 milliseconds and 125 milliseconds reconstructions (both P 's > 0.05), respectively. Stent blooming artifacts were significantly lower on 66 milliseconds than on 125 milliseconds reconstructions (46.7% ± 10% vs 52.9% ± 8.9%, P < 0.001). Higher sharpness was found in 66 milliseconds than in 125 milliseconds reconstructions both in native coronary arteries (left anterior descending artery: 1031 ± 265 ∆HU/mm vs 819 ± 253 ∆HU/mm, P < 0.01; right coronary artery: 884 ± 352 ∆HU/mm vs 654 ± 377 ∆HU/mm, P < 0.001) and stents (5318 ± 3874 ∆HU/mm vs 4267 ± 3521 ∆HU/mm, P < 0.001). CONCLUSIONS: Coronary angiography with PCD-CT in the UHR mode profits considerably from a high temporal resolution, resulting in less motion artifacts, superior vessel delineation and in-stent lumen visualization, less stent blooming artifacts, and superior vessel and stent sharpness.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Stents , Imagens de Fantasmas
19.
J Heart Lung Transplant ; 42(2): 209-217, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-37071121

RESUMO

BACKGROUND: Chronic lung allograft dysfunction (CLAD) is a leading cause of graft loss in lung transplantation. Despite this, convincing treatment data is lacking, and protocols vary widely between centers. CLAD phenotypes exist, but phenotype transitioning has increased the challenge of designing clinically relevant studies. Extracorporeal photopheresis (ECP) has long been a suggested salvage treatment, but efficacy appears unpredictable. This study describes our experiences with photopheresis, using novel temporal phenotyping to illustrate the clinical course. METHODS: Retrospective analysis of patients completing ≥3 months of ECP for CLAD between 2007 and 2022 was performed. A latent class analysis employing a mixed-effects model was performed, deriving patient subgroups based on spirometry trajectory over the 12 months prior to photopheresis until graft loss or 4 years post photopheresis initiation. The resulting temporal phenotypes were compared in terms of treatment response and survival outcomes. Linear discriminatory analysis was used to assess phenotype predictability, relying solely on data available at photopheresis initiation. RESULTS: Data from 5,169 outpatient attendances in 373 patients was used to construct the model. Five trajectories were identified, with uniform spirometry changes evident following 6 months of photopheresis. Outcomes were poorest in Fulminant patients (N = 25, 7%) with median survival of 1 year. In the remainder, poorer lung function at initiation led to poorer outcomes. The analysis revealed important confounders, affecting both decision-making and outcome interpretation. CONCLUSIONS: Temporal phenotyping provided novel insights into ECP treatment response in CLAD, particularly the importance of timely intervention. Limitations in % Baseline values in guiding treatment decisions warrant further analysis. Photopheresis may have a more uniform effect than previously thought. Predicting survival at ECP initiation appears feasible.


Assuntos
Bronquiolite Obliterante , Doença Enxerto-Hospedeiro , Fotoferese , Humanos , Fotoferese/métodos , Estudos Retrospectivos , Pulmão , Resultado do Tratamento
20.
Eur Radiol ; 33(8): 5309-5320, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37020069

RESUMO

The X-ray detector is a fundamental component of a CT system that determines the image quality and dose efficiency. Until the approval of the first clinical photon-counting-detector (PCD) system in 2021, all clinical CT scanners used scintillating detectors, which do not capture information about individual photons in the two-step detection process. In contrast, PCDs use a one-step process whereby X-ray energy is converted directly into an electrical signal. This preserves information about individual photons such that the numbers of X-ray in different energy ranges can be counted. Primary advantages of PCDs include the absence of electronic noise, improved radiation dose efficiency, increased iodine signal and the ability to use lower doses of iodinated contrast material, and better spatial resolution. PCDs with more than one energy threshold can sort the detected photons into two or more energy bins, making energy-resolved information available for all acquisitions. This allows for material classification or quantitation tasks to be performed in conjunction with high spatial resolution, and in the case of dual-source CT, high pitch, or high temporal resolution acquisitions. Some of the most promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value. These include imaging of the inner ear, bones, small blood vessels, heart, and lung. This review describes the clinical benefits observed to date and future directions for this technical advance in CT imaging. KEY POINTS: • Beneficial characteristics of photon-counting detectors include the absence of electronic noise, increased iodine signal-to-noise ratio, improved spatial resolution, and full-time multi-energy imaging. • Promising applications of PCD-CT involve imaging of anatomy where exquisite spatial resolution adds clinical value and applications requiring multi-energy data simultaneous with high spatial and/or temporal resolution. • Future applications of PCD-CT technology may include extremely high spatial resolution tasks, such as the detection of breast micro-calcifications, and quantitative imaging of native tissue types and novel contrast agents.


Assuntos
Compostos de Iodo , Iodo , Humanos , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Meios de Contraste , Fótons , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...